Protect-It Maxi Installation

Each Protect-It MaxiTM has 4 pin location holes, two on each side into which the connection pins can be inserted. This choice of holes makes Protect-It MaxiTM expandable to suit multiple column sizes. The best pin location hole for the application will depend on the column size requiring the protection. As a guide, the inner holes are generally used for corners.

Installation Image

 Column Size

 MAXIPAC's Required for 20" H

MAXIPAC's Required for 40" H 

 4" x 4" (100mm x 100mm)

6" x 6" (150mm x 150mm)

 0.5

 1

 8" x 8" (200mm x 200mm)

9" x 9" (225mm x 225mm)

10" x 10" (250mm x 250mm)

11" x 11" (275mm x 275mm)

12" x 12" (300mm x 300mm)

& rectangular combinations

 1

 2

 12" x 12" (300mm x 300mm)

13" x 13" (325mm x 325mm)

14" x 14" (350mm x 350mm)

15" x 15" (375mm x 375mm)

16" x 16" (400mm x 400mm)

17" x 17" (425mm x 425mm)

18" x 18" (450mm x 450mm)

19" x 19" (475mm x 475mm)

& rectangular combinations

 1.5

 3

 18" x 18" (450mm x 450mm)

19" x 19" (475mm x 475mm)

20" x 20" (500mm x 500mm)

21" x 21" (525mm x 525mm)

22" x 22" (550mm x 550mm)

23" x 23" (575mm x 575mm)

24" x 24" (600mm x 600mm)

& rectangular combinations

 2

 4

 Round 4" (175mm)

Round 5" (200mm)

Round 6" (225mm)

0.5 

1

Round 7" (175mm)

Round 8" (200mm)

Round 9" (225mm) 

0.75 

1.5 

 Round 10" (250mm)

Round 11" (275mm)

Round 12" (300mm)

Round 13" (325mm)

Round 14" (350mm)

 2

                             Step By Step Photos    (click on an image to enlarge)

    Step 1      Step 2      Step 3      Step 4     

                             Please click here for the printable PDF Installation Guide

    Step 5      Step 6      Step 7      Step 8